{"product_id":"avalon-q-repair-service","title":"Avalon Q Repair Service","description":"\u003cp\u003e\u003cstrong\u003eAvalon Q repair, done at chip level:\u003c\/strong\u003e when the unit spins up, hashes at full rate for a few seconds, and falls back to Idle, the trigger is usually a single A3197 ASIC reporting a false 190 °C. We locate that chip, replace it — included in the flat price — and prove the fix on the miner’s own dashboard.\u003c\/p\u003e\n\u003cp\u003eThe Canaan Avalon Q packs a full 90 TH\/s of SHA-256 Bitcoin hashing into a single enclosed home unit: one 160-chip board, an integrated PSU4100-03 supply with voltage feedback to a Kendryte-class controller, and vendor-proprietary Canaan firmware. Proprietary firmware means recovery ends where Canaan’s own tools end — past that point the work is component-level, and that is what our lab does. We service the machine as one system: board, power path, cooling tract, and the per-chip telemetry that ties them together.\u003c\/p\u003e\n\u003ch2\u003eTechnical Diagnostics and Common Issues with the Avalon Q\u003c\/h2\u003e\n\u003ch3\u003eQuick Symptom Checklist\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe miner starts, hashes briefly at full rate, then the log settles on \u003ccode\u003eSYSTEMSTATU[Work: In Idle, Hash Board: 1]\u003c\/code\u003e with \u003ccode\u003eSoftOFF[3]\u003c\/code\u003e and idle draw around 110–125 W\u003c\/li\u003e\n\u003cli\u003eOne entry in the 160-chip PVT temperature array reads 178–197 °C while the other 159 sit near room temperature — and its PVT voltage drops out of line with its neighbors\u003c\/li\u003e\n\u003cli\u003e\n\u003ccode\u003eerror #03\u003c\/code\u003e on the device, or \u003ccode\u003eFanErr[1]\u003c\/code\u003e over the API — a fan fault, sometimes with nothing wrong with the fan itself\u003c\/li\u003e\n\u003cli\u003eThe web dashboard flashes “ASIC Status: Error” in red during startup, then settles on yellow Idle\u003c\/li\u003e\n\u003cli\u003e\n\u003ccode\u003eECMM[64]\u003c\/code\u003e appears in the idle state after a protective shutdown\u003c\/li\u003e\n\u003cli\u003eHashrate sags and \u003ccode\u003eTMax\u003c\/code\u003e climbs over weeks while the \u003ccode\u003eFilter[…]\u003c\/code\u003e runtime counter is high — a clogged intake filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTry This Before You Ship It In\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull power cycle from the rear switch\u003c\/strong\u003e — off, 30 seconds, on. Not a soft reboot from the dashboard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf you see \u003ccode\u003eerror #03\u003c\/code\u003e or \u003ccode\u003eFanErr[1]\u003c\/code\u003e soon after delivery\u003c\/strong\u003e: open the side panel and check whether one of the internal acoustic damping pads has shifted into a 120 mm fan during transport. Owners have cleared this exact fault by re-seating a loose pad.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePull and rinse the front mesh filter\u003c\/strong\u003e — it slides out behind the front grille without disassembly. The firmware even tracks filter runtime in minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWi-Fi checks\u003c\/strong\u003e: the USB Wi-Fi module supports 2.4 GHz only. Switching to Ethernet requires removing the module, powering off for 10 seconds, then connecting the cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify pool settings\u003c\/strong\u003e — address, port, and worker format per your pool’s rules; solo-style pools expect your BTC address as the worker name.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReinstall stock firmware\u003c\/strong\u003e via the Avalon Family app or a FAT32 USB drive. Note your pools first: a 5-second reset wipes them and returns the password to \u003ccode\u003eadmin\u003c\/code\u003e. See our \u003ca href=\"\/pages\/firmware\"\u003efirmware help\u003c\/a\u003e resource.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn 110 V circuits\u003c\/strong\u003e: if the unit only misbehaves in Super mode, test in Eco — a sagging shared circuit near its 15 A limit looks exactly like a hardware fault.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapture the evidence\u003c\/strong\u003e: \u003ccode\u003eecho '{\"command\":\"litestats\"}' | nc -w 2 \u0026lt;miner-ip\u0026gt; 4028\u003c\/code\u003e — paste the output into your repair order notes. It shortens diagnosis by a day.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eIf none of this changes the behavior, the fault is in the hardware — and here is what we do next.\u003c\/p\u003e\n\u003ch3\u003eModel-Specific Patterns on the Avalon Q\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOne chip poisons the whole board.\u003c\/strong\u003e Every A3197 carries its temperature and voltage sensing on the die itself. When a single chip starts reporting 178–197 °C on a cold board — with its sensed voltage sitting at 221 against 271–279 on its neighbors — the protection logic reads a real fire where there is none and shuts hashing down seconds after start. Because the sensor lives on the die, a paired temperature-and-voltage anomaly on one index points at that chip or its solder joints, not at external circuitry. The fix is locating the physical position behind the logical index and replacing that one ASIC — which is included in this service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransport shakes the acoustic lining loose.\u003c\/strong\u003e The Avalon Q’s near-silent 45 dB operation comes from internal foam damping — and a pad that detaches in shipping can jam one of the four 120 mm fans, throwing \u003ccode\u003eerror #03\u003c\/code\u003e on electronics that are perfectly healthy. It is the first thing we rule out on any fan fault, and the first thing you should too.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe filter is a consumable.\u003c\/strong\u003e An enclosed case with a sealed airflow channel keeps the unit quiet, but it concentrates all intake through one mesh filter. Left unserviced, \u003ccode\u003eTMax\u003c\/code\u003e and \u003ccode\u003eTAvg\u003c\/code\u003e creep toward the throttle point and the unit derates or drops out — a failure that a rinse and a thermal-interface refresh reverses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuper mode tests your wiring, not just the miner.\u003c\/strong\u003e At full output the integrated supply pulls roughly 1674 W from the wall — close to the practical ceiling of a shared 110 V household circuit. Restarts and idle drops that happen only in Super and vanish in Eco are usually the circuit sagging, not the machine failing.\u003c\/p\u003e\n\u003ch3\u003eHardware Notes\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlgorithm\u003c\/td\u003e\n\u003ctd\u003eSHA-256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoin(s) targeted\u003c\/td\u003e\n\u003ctd\u003eBitcoin (BTC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice type\u003c\/td\u003e\n\u003ctd\u003eComplete self-contained home miner — one integrated unit, not a removable Antminer-style hashboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure format\u003c\/td\u003e\n\u003ctd\u003eEnclosed case, 455×130×440 mm, 10.5 kg; removable front mesh filter; internal acoustic lining\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal board\u003c\/td\u003e\n\u003ctd\u003eSingle board, 160× \u003ca href=\"\/products\/a3197-asic-chip\"\u003eA3197 ASIC\u003c\/a\u003e (package-marked A3197MC; firmware reports the core as \u003ccode\u003eA3197S\u003c\/code\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003eCanaan Kendryte-class control board; 0.91″ OLED showing IP, hashrate, power, and mode; separate fan daughter board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eCanaan vendor-proprietary (cgminer-based); Avalon Family app + web GUI; CGMiner-compatible API on port 4028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated hashrate\u003c\/td\u003e\n\u003ctd\u003e90 TH\/s Super · 80.71 TH\/s Standard · 54.19 TH\/s Eco (±3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFour 120 mm fans (two intake, two exhaust), oversized spring-mounted heatsinks, sealed airflow channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003eIntegrated PSU4100-03, 110–240 V AC, up to ~1674 W at the wall in Super mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDiagnostics Focus\u003c\/h3\u003e\n\u003cp\u003eTwo things get read before anything gets touched. First, the full per-chip telemetry: the Avalon Q exposes temperature and voltage for each of its 160 ASICs, so a single failing position is visible from the array — no probing required to find the suspect. Second, the power path: the PSU4100-03 reports to the controller directly, and separating a supply-side event from a board-side one is what keeps a chip swap from being done on a machine whose real problem is upstream.\u003c\/p\u003e\n\u003ch3\u003eDiagnostic Decision Tree\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSymptom\u003c\/th\u003e\n\u003cth\u003eLikely cause\u003c\/th\u003e\n\u003cth\u003eWhat we check first\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHashes for seconds, drops to Idle; one PVT entry at 178–197 °C\u003c\/td\u003e\n\u003ctd\u003eSingle ASIC with corrupted on-die sensing\u003c\/td\u003e\n\u003ctd\u003eMap the logical index to the physical position; inspect the joint; replace the chip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ccode\u003eerror #03\u003c\/code\u003e \/ \u003ccode\u003eFanErr[1]\u003c\/code\u003e right after delivery\u003c\/td\u003e\n\u003ctd\u003eDisplaced damping pad or a failed fan\u003c\/td\u003e\n\u003ctd\u003eSide panel off; pad positions; fan spin test on all four\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ccode\u003eTMax\u003c\/code\u003e climbing over weeks, hashrate sagging\u003c\/td\u003e\n\u003ctd\u003eClogged filter \/ aged thermal interface\u003c\/td\u003e\n\u003ctd\u003e\n\u003ccode\u003eFilter[…]\u003c\/code\u003e counter; filter wash; interface refresh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRestarts or Idle drops only in Super mode on 110 V\u003c\/td\u003e\n\u003ctd\u003eCircuit sag under load\u003c\/td\u003e\n\u003ctd\u003eBehavior in Eco; supply quality; dedicated-circuit advice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnreachable on the network, otherwise running\u003c\/td\u003e\n\u003ctd\u003eWi-Fi module \/ band \/ switch procedure\u003c\/td\u003e\n\u003ctd\u003e2.4 GHz check; module reseat; wired-connection procedure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eOur Professional Repair Process\u003c\/h2\u003e\n\u003ch3\u003eGotchas\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHashrate alone does not validate this repair.\u003c\/strong\u003e After a chip replacement, a healthy-looking terahash figure can still hide a marginal joint — the honest check is the 160-entry PVT array reading flat, temperatures and voltages both, before and through burn-in. Per-chip telemetry is what makes this machine diagnosable; it is also the bar the repair has to clear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe chip answers to two names.\u003c\/strong\u003e Packages are marked A3197MC while the firmware reports the core as \u003ccode\u003eA3197S\u003c\/code\u003e — the same silicon series. Owners sourcing parts by the sticker sometimes conclude they have the “wrong” chip; they usually do not.\u003c\/p\u003e\n\u003ch3\u003eTypical Service Scenario\u003c\/h3\u003e\n\u003cp\u003eThe most common intake in this model looks like the checklist above brought to life: an owner arrives with their own API printout showing 159 chips at room temperature and one at 195 °C. We reproduce the reading on the bench, translate the logical index into a physical position on the board, replace the single ASIC, and run the unit against its own dashboard until the array reads flat. A close second is the “fan error out of the box” — a unit that shipped fine and arrived throwing \u003ccode\u003eerror #03\u003c\/code\u003e — where the repair is mechanical: lining re-seated, fans verified, nothing soldered. Third is the seasonal thermal service: filter, pads, and interface on a unit that has quietly derated through a summer.\u003c\/p\u003e\n\u003ch3\u003eWhat Happens After Intake\u003c\/h3\u003e\n\u003cp\u003eEvery unit follows the same path: intake photos and a \u003ccode\u003elitestats\u003c\/code\u003e capture before anything is opened → incoming inspection → diagnostics on the machine’s own API and web dashboard → component-level work, with one ASIC replacement included in the flat service price → cleaning, filter service, and thermal-interface renewal → validation. Validation happens on the Avalon Q’s own reporting surface, not on external board testers: all 160 ASICs enumerated, \u003ccode\u003eFanErr[0]\u003c\/code\u003e, a flat PVT array, and rated hashrate for the selected mode held through a minimum 2-hour burn-in. Extended burn-in is available as an add-on.\u003c\/p\u003e\n\u003cp\u003eEvery Avalon Q on our bench goes through \u003ca href=\"\/pages\/aleksandr-muranov\"\u003eAlex — seven years of component-level ASIC work\u003c\/a\u003e — and nothing ships back until he signs the burn-in log.\u003c\/p\u003e\n\u003cp\u003eIf your Avalon Q matches any pattern above, book the repair from this page — and paste your \u003ccode\u003elitestats\u003c\/code\u003e output into the order notes. Ship the complete unit with its Wi-Fi module and power cord; the board, supply, controller, and cooling tract diagnose reliably only as the single system Canaan built them to be.\u003c\/p\u003e","brand":"Antminer Repair","offers":[{"title":"Default Title","offer_id":54407182745873,"sku":"SOLO-AVA-Q","price":250.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/antminer-repair.com\/products\/avalon-q-repair-service","provider":"Antminer Repair","version":"1.0","type":"link"}